Why emergency lighting is tested

Emergency lighting helps people leave a building safely if the normal supply fails — on escape routes, at exits, in open areas and where tasks create higher risk. Batteries age, lamps fail and self-test modules can drift out of specification. Planned testing finds faults before they matter and creates the paper trail insurers, fire officers and managing agents often request. Good practice for many UK non-domestic systems is framed by BS 5266 alongside your fire risk assessment.

Monthly checks vs annual full tests

Monthly function test

A short simulated mains failure (typically a few minutes) to confirm each luminaire or exit sign illuminates correctly. Results should be recorded in the site logbook. Self-testing fittings still need review of indicators and any fault reports.

Annual full-duration test

A full rated discharge (often three hours for many installations, subject to system design) followed by recharge checks. Competent engineers commonly complete this with certificates, battery recommendations and schedule updates.

Exact intervals and durations depend on system type (maintained, non-maintained, central battery, self-test) and your risk assessment — always follow manufacturer guidance and the design documentation for the site.

What an engineer visit usually covers

  • Visual inspection of fittings, exit signs and supply arrangements
  • Function and/or full-duration discharge testing as scheduled
  • Battery condition, charge status and replacement recommendations where due
  • Review of self-test logs or central monitoring outputs where fitted
  • Logbook update and certification for audits and insurers

Pair emergency lighting work with fire alarm servicing where both sit in the same life-safety programme — one visit day often reduces disruption for multi-let and commercial sites.

Maintained, non-maintained and self-test

Maintained

Luminaires lit in normal use and on emergency supply — common for exit signs and some open areas.

Non-maintained

Illuminates only when the normal supply fails — frequent on escape routes and plant areas.

Self-test / automatic

On-board or networked testing reduces manual work, but faults still need investigation and records.

Keep clear records

Maintain a log (paper or digital) of monthly tests, annual discharge results, battery changes, new fittings and defects. After layout changes, refurbishments or a new fire risk assessment, review coverage — missing exit signs and dark corners are common findings on older stock.

When to consider an upgrade

Repeated battery failures, obsolete fluorescent packs, incomplete coverage after fit-outs, or a move to LED self-test systems are typical upgrade drivers. We can survey existing installations and quote replacements that align with current practice and your risk assessment.

Related Icomply services

Book emergency lighting testing

Share the postcode, number of fittings and last test date — we quote annual tests, battery replacements and multi-site contracts across the North West.

← Back to resources · FAQ · Emergency lighting service hub

Free quote

Request an emergency lighting quote

Annual full tests, remedial works or planned maintenance with full documentation.

By submitting you agree to our Privacy Policy and Terms.

💬