EICR codes C1, C2, C3 and FI explained

What each observation code on an electrical report means, which ones fail the report, and what landlords must do next.

Modern consumer unit with circuit breakers

Updated 5 November 2026

Quick answer

C1 means danger is present and needs immediate action. C2 means potentially dangerous and needs urgent remedial work. FI means further investigation is needed without delay. Any C1, C2 or FI makes the report unsatisfactory. C3 is an improvement recommendation and doesn't fail the report on its own.

The codes

CodeMeaningReport result
C1Danger present: risk of injury, immediate action requiredUnsatisfactory
C2Potentially dangerous: urgent remedial action requiredUnsatisfactory
FIFurther investigation required without delayUnsatisfactory
C3Improvement recommendedSatisfactory if no other codes

Common examples

  • C1: exposed live conductors, a broken socket with live parts accessible
  • C2: no earthing, missing RCD protection where required, signs of overheating
  • C3: older equipment that still works but doesn't meet current standards
  • FI: a circuit that couldn't be traced or tested

What landlords must do

Carry out remedial work within 28 days or sooner if the report says, and get written confirmation from a qualified person. Give a copy to the tenant and, if asked, the local authority.

Questions we get asked

Will a C3 fail my EICR?

No. C3s are recommendations, though fixing them can avoid future problems.

Can you fix the codes found by another electrician?

Yes. Send us the report and we'll price the remedials.

Need this done?

Tell us the address and what you need, or send a photo. We reply quickly with a clear written quote, covering across Lancashire, Greater Manchester and Merseyside.

Get a free quote Call 07517 806082

From our recent jobs

Photos from our own jobs. Codes, people and other firms' details are blurred.

Three-phase distribution board with dedicated fire alarm and emergency lighting circuits
Three-phase distribution board with dedicated, labelled fire alarm and emergency lighting circuits.
Armoured cables glanded into steel back boxes during an electrical first fix
Armoured cables glanded into steel back boxes at first fix.
Metal-clad consumer unit installed ready for connection
Metal-clad consumer unit installed and ready for connection.

Need a certificate, a repair or a quote?

Tell us the address and what you need. We reply the same working day.