Air conditioning explained
Indoor units, outdoor units, refrigerant rules and when you need leak checks.
In plain English
A split air conditioning system has an indoor unit that blows cool (or warm) air and an outdoor unit that moves heat outside. Refrigerant gas flows between them through insulated copper pipes.
What the law says
UK F-gas Regulations
Only F-gas certified engineers working for a certified company can install or service systems containing refrigerant. Systems holding refrigerant equal to 5 tonnes of CO2 or more must be leak checked at least yearly (more often for bigger systems).
Energy Performance of Buildings Regulations
Air con systems with a combined output over 12 kW need an energy inspection (TM44 report) at least every 5 years.
Standards we work to
- BS EN 378 — Safety and environmental requirements for refrigerating systems and heat pumps.
Who is responsible?
The 'operator' — usually the building owner or tenant who controls the system.
The components we install
These are the parts that make up a typical air conditioning installation, what each one does, and what a healthy one looks like.
Indoor unit
Wall-mounted, ceiling cassette or ducted. Blows conditioned air into the room.
What to look for: Clean filters, no drips.
Outdoor unit
Holds the compressor and fan. Rejects heat outside.
What to look for: Clear airflow, no debris.
Refrigerant pipework
Two insulated copper pipes between the units.
What to look for: Insulation intact, not crushed.
Condensate drain / pump
Carries away water the unit takes out of the air.
What to look for: No leaks or overflow.
Controller / remote
Sets temperature, mode and timer.
What to look for: Works, batteries good.
Isolator
Lets engineers safely cut power at the outdoor unit.
What to look for: Weatherproof.
Filters
Catch dust before it gets into the coil.
What to look for: Clean them every few weeks in heavy use.
How often it must be checked
- YearlyService: filters, coils, drains, refrigerant and electrics checked.By: F-gas certified engineer
- Yearly or moreLeak check if the system is 5 tonnes CO2 equivalent or more.By: F-gas certified engineer
- Every 5 yearsTM44 inspection for systems over 12 kW.By: Accredited energy assessor
Paperwork you should get
- F-gas records — Refrigerant type, amount, leak checks and repairs.
- Commissioning sheet — Pressure test and settings on install.
- TM44 report — Where required.
Simple checks you can do
- Clean or vacuum filters regularly.
- Keep the outdoor unit clear of leaves and bins.
- Report water leaks or ice on pipes.
Common questions
Does my small home system need a leak check?
Usually not. A typical single split unit holds less than 5 tonnes CO2 equivalent. We'll tell you on install.
Need this installed, tested or certified?
We install, service and certify this equipment and hand you every certificate in plain English.
Related guides
This guide is a plain-English summary to help you understand your duties. It is not legal advice, and rules can change. Your fire risk assessment, insurer or local council may ask for more.
Manufacturers we work with
We install, service and repair equipment from all of these manufacturers. The most relevant for this page are shown first.
Need a certificate, a repair or a quote?
Tell us the address and what you need. We reply the same working day.