Electrical installations and EICRs explained

Fuse boards, RCDs and what the codes on your EICR actually mean.

Who's responsibleLandlords for rented homes, employers and building owners for workplaces and common parts, homeowners for their own homes
Most frequent checkEvery 5 years (max)
Parts explained9 components

In plain English

Your electrical installation is everything from the meter onwards: the consumer unit (fuse board), the circuits, sockets, switches, lights and earthing. An EICR (Electrical Installation Condition Report) is a health check of all of it.

Why it matters: Faulty wiring causes shocks and fires. Old fuse boards often lack RCDs — the device that cuts the power in a split second if someone touches a live part.

What the law says

  • Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020

    Landlords must have the electrics inspected and tested at least every 5 years, give tenants a copy of the report within 28 days, give it to the council within 7 days if asked, and finish any required repairs within 28 days (or sooner if the report says so).

  • Electricity at Work Regulations 1989

    Employers must keep electrical systems safe. Regular inspection is the normal way to show you're doing this.

  • Building Regulations — Part P

    Certain domestic electrical work (new circuits, consumer unit changes, work in bathrooms) must be done by a registered electrician or signed off by building control.

Standards we work to

  • BS 7671 — The IET Wiring Regulations — the UK standard every installation is designed, tested and reported against.

Who is responsible?

Landlords for rented homes, employers and building owners for workplaces and common parts, homeowners for their own homes.

The components we install

These are the parts that make up a typical electrical installations and eicrs installation, what each one does, and what a healthy one looks like.

  • Consumer unit / distribution board

    The fuse board. Splits the supply into circuits and holds the protective devices.

    What to look for: Non-combustible (usually metal) case in homes, labelled circuits, no scorch marks.

  • Main switch

    Turns off the whole installation.

    What to look for: Easy to find and reach.

  • MCB (circuit breaker)

    Trips if a circuit is overloaded or short-circuits. Replaces old rewireable fuses.

    What to look for: Labelled for each circuit.

  • RCD

    Trips if current leaks to earth — for example through a person. Saves lives.

    What to look for: Test button trips it.

  • RCBO

    An MCB and RCD in one, so a fault only cuts one circuit.

    What to look for: Test button trips it.

  • Surge protection device (SPD)

    Protects equipment from voltage spikes, like lightning strikes.

    What to look for: Status window shows green.

  • AFDD

    Detects dangerous sparking (arcs) in damaged cables and switches off before a fire starts.

    What to look for: Fitted in higher-risk premises like HMOs and care homes.

  • Earthing and bonding

    Green/yellow cables connecting the installation and metal pipes to earth so faults are cleared safely.

    What to look for: Clamps on gas and water pipes, labelled.

  • Sockets and switches

    The accessories you use every day.

    What to look for: No cracks, scorch marks or warmth.

How often it must be checked

  • Every 5 years (max)EICR for privately rented homes and most commercial premises.By: Qualified electrician
  • Every 10 yearsRecommended EICR for owner-occupied homes, or when buying a property.By: Qualified electrician
  • More oftenSome premises like swimming pools, caravan parks or industrial sites need shorter intervals.By: Qualified electrician
  • Every 3 monthsPress the 'T' test button on each RCD.By: You

See the testing schedule for every system →

Paperwork you should get

  • EIC (Electrical Installation Certificate) — Issued for new circuits or a full rewire.
  • Minor Works Certificate — Issued for small jobs like adding a socket.
  • EICR — The condition report. It will say 'Satisfactory' or 'Unsatisfactory'.
  • Part P notification — Building regulations compliance certificate for notifiable domestic work.

Certificates explained →

Simple checks you can do

  • Test your RCDs every three months.
  • Look for scorch marks, buzzing or warm sockets.
  • Don't daisy-chain extension leads.
  • Landlords: diary the 5-year EICR date.

Common questions

What do C1, C2 and C3 mean?

C1 = danger present, needs fixing immediately. C2 = potentially dangerous, needs fixing urgently. C3 = improvement recommended. FI = further investigation needed. Any C1, C2 or FI makes the report 'Unsatisfactory'.

My EICR failed. What now?

In a rental you must have the C1, C2 and FI items fixed within 28 days (or sooner) and get written confirmation to give to the tenant and council.

Need this installed, tested or certified?

We install, service and certify this equipment and hand you every certificate in plain English.