Fire alarm systems explained

How a fire alarm finds a fire, warns everyone, and what the law expects you to test.

Who's responsibleThe 'responsible person' — usually the employer, owner, landlord or managing agent
Most frequent checkWeekly
Parts explained11 components

In plain English

A fire alarm system is a set of detectors, call points and sounders wired back to a control panel. When a detector senses smoke or heat, or someone presses a red call point, the panel sets off every sounder so people get out early.

Why it matters: Most people who die in fires are overcome by smoke before they see flames. An alarm buys minutes, and minutes are what let people escape.

What the law says

  • Regulatory Reform (Fire Safety) Order 2005

    If you control a business, a workplace or the shared parts of a block of flats or HMO, you must have suitable ways of detecting a fire and warning people, and you must keep them maintained. Your fire risk assessment decides what 'suitable' means for your building.

  • Housing Act 2004 (HMOs)

    Councils expect HMOs to have a fire alarm suited to their size and layout. Licensed HMOs usually have the alarm written into the licence conditions.

Standards we work to

  • BS 5839-1 — The rulebook for fire alarms in non-domestic buildings and the common parts of flats. It sets out system categories (L1 to L5 for protecting life, P1/P2 for protecting property, M for manual only), how to design, install, commission and service them.
  • BS 5839-6 — The rulebook for alarms in homes, including HMOs and flats. It uses Grades (how the system is built, A to F) and Categories (how much of the home is covered).

Who is responsible?

The 'responsible person' — usually the employer, owner, landlord or managing agent. You can hand the work to a competent company (like us), but the legal duty to make sure it's done stays with you.

The components we install

These are the parts that make up a typical fire alarm systems installation, what each one does, and what a healthy one looks like.

  • Control and indicating panel

    The 'brain'. It watches every device, shows which zone has gone into alarm or fault, and switches the sounders on.

    What to look for: Green 'power' light on, no fault lights, zone chart beside it.

  • Optical smoke detector

    Senses smoke particles in the air. Used in most rooms, corridors and stairs.

    What to look for: Clean, no dust caps or paint on it, not covered up.

  • Heat detector

    Goes off at a set temperature or when heat rises quickly. Used in kitchens and dusty areas where smoke detectors would false alarm.

    What to look for: Fitted on the ceiling, not boxed in by cupboards.

  • Multi-sensor detector

    Combines smoke and heat sensing to cut down false alarms.

    What to look for: Same as smoke detectors.

  • Manual call point

    The red 'break glass' box. Press it to raise the alarm by hand. Placed by exits and on each floor landing.

    What to look for: Clear access, not blocked, plastic element not cracked.

  • Sounder

    Makes the alarm noise. Must be loud enough to hear everywhere, including bedrooms in sleeping risk buildings.

    What to look for: Not painted over or covered.

  • Visual alarm device (beacon)

    A flashing red or white light for people who are deaf or hard of hearing, or noisy areas.

    What to look for: Lens clean and visible.

  • Standby batteries

    Keep the system working if the mains fails, usually for at least 24 hours plus 30 minutes in alarm.

    What to look for: Dated label inside the panel. Typically replaced every 4–5 years.

  • Fire-resistant cable

    Red or white fire-rated cable (often called FP cable) that keeps working in a fire long enough for the alarm to sound.

    What to look for: Clipped with metal fixings, not plastic ties alone.

  • Interface / relay module

    Lets the alarm talk to other systems: releasing door holders, opening smoke vents, sending lifts to ground, shutting off gas.

    What to look for: Labelled, no fault showing on the panel.

  • Magnetic door holder

    Holds fire doors open day to day and lets them close automatically when the alarm sounds.

    What to look for: Door closes fully when the alarm is tested.

How often it must be checked

  • WeeklySet off one manual call point and check the sounders work. Use a different call point each week and write it in the log book.By: You or your staff
  • Every 6 months (max)Full inspection and service: detectors tested, batteries checked, panel and faults checked, certificate issued.By: Competent fire alarm engineer
  • YearlyOver each 12 months, every detector and call point should have been tested at least once (often split across the two services).By: Competent fire alarm engineer

See the testing schedule for every system →

Paperwork you should get

  • Design, installation and commissioning certificates — Issued when a new system is put in. They prove the system was designed and installed to BS 5839.
  • Acceptance certificate — Signed when you formally take over the new system.
  • Inspection and servicing certificate — Issued after every service. Keep them — fire officers and insurers ask to see them.
  • Fire alarm log book — Where weekly tests, false alarms, faults and services are recorded.
  • Zone plan — A simple drawing next to the panel showing which zone covers which area, so the fire service can find the fire fast.

Certificates explained →

Simple checks you can do

  • Do the weekly call point test and log it.
  • Check the panel shows no faults every day.
  • Keep detectors uncovered, especially during decorating.
  • Report false alarms in the log book so the engineer can look for a pattern.
  • Make sure everyone knows what the alarm sounds like and where to go.

Common questions

Can I just fit battery smoke alarms instead?

In a single home, sometimes. In a business, common parts of flats or most HMOs, no — you'll normally need a proper system to BS 5839. Your fire risk assessment will say which.

What do L1, L2, L3 mean?

How much of the building has detection. L1 is everywhere. L2 is escape routes plus high-risk rooms. L3 is escape routes plus rooms that open onto them. Your risk assessment sets the category.

Why does it keep false alarming?

Usually dust, steam, cooking fumes, the wrong detector in the wrong place or a failing device. Logging every false alarm helps us find and fix the cause.

Need this installed, tested or certified?

We install, service and certify this equipment and hand you every certificate in plain English.

Related guides

This guide is a plain-English summary to help you understand your duties. It is not legal advice, and rules can change. Your fire risk assessment, insurer or local council may ask for more.

Need a certificate, a repair or a quote?

Tell us the address and what you need. We reply the same working day.