Sprinkler systems explained

How sprinklers control a fire automatically — and why only the heads near the fire go off.

Who's responsibleThe building owner or responsible person
Most frequent checkWeekly (commercial)
Parts explained7 components

In plain English

Sprinklers are water pipes in the ceiling with heads that each open on their own when they get hot. Only the heads above the fire operate, spraying water to control or put out the fire while it's still small.

Why it matters: Sprinklers act within minutes, often before the fire service arrives. They massively reduce deaths, injuries and damage.

What the law says

  • Building Regulations — Approved Document B

    New blocks of flats over 11 metres in England must have sprinklers (since November 2020). Some care homes, large warehouses and other buildings need them too.

  • Regulatory Reform (Fire Safety) Order 2005

    Once fitted, sprinklers must be maintained.

Standards we work to

  • BS EN 12845 — Design, installation and maintenance of commercial sprinkler systems.
  • BS 9251 — Sprinklers for homes, flats, HMOs and care homes.

Who is responsible?

The building owner or responsible person.

The components we install

These are the parts that make up a typical sprinkler systems installation, what each one does, and what a healthy one looks like.

  • Sprinkler head

    Has a small glass bulb full of liquid. At about 68°C (red bulb) the bulb bursts and water flows.

    What to look for: Not painted, not covered, not hung on.

  • Pipework

    Usually steel or special plastic (CPVC) running to each head.

    What to look for: No leaks, no corrosion, not used as a hanger.

  • Alarm valve set

    The main control point. Detects water flowing and raises the alarm.

    What to look for: Valves locked in the correct position.

  • Water supply / tank

    Mains or a stored tank big enough to run the system for the design time.

    What to look for: Tank full, no leaks.

  • Pump set

    Boosts pressure where mains water isn't enough.

    What to look for: Runs on weekly test.

  • Flow switch

    Tells the fire alarm that water is flowing.

    What to look for: Linked to the alarm panel.

  • Test and drain valve

    Used by engineers to test the system.

    What to look for: Closed and labelled.

How often it must be checked

  • Weekly (commercial)Check pressures, water levels, valves, and run pumps.By: Site staff
  • Yearly (minimum)Full service and inspection.By: Competent sprinkler engineer

See the testing schedule for every system →

Paperwork you should get

  • Installation / commissioning certificate — Proves the system matches its design.
  • Service report — After each service.
  • Log book — Weekly checks and any operations recorded.

Certificates explained →

Simple checks you can do

  • Keep at least 0.5 m clear below heads (more for storage).
  • Never paint a head or hang things from pipes.
  • Check valves are locked open and pressures look normal.

Common questions

Will all the sprinklers go off at once like in films?

No. Each head works on its own heat. Most fires are controlled by one or two heads.

Need this installed, tested or certified?

We install, service and certify this equipment and hand you every certificate in plain English.

Related guides

This guide is a plain-English summary to help you understand your duties. It is not legal advice, and rules can change. Your fire risk assessment, insurer or local council may ask for more.

Need a certificate, a repair or a quote?

Tell us the address and what you need. We reply the same working day.