Fire safety
Sprinkler systems explained
How sprinklers control a fire automatically — and why only the heads near the fire go off.
In plain English
Sprinklers are water pipes in the ceiling with heads that each open on their own when they get hot. Only the heads above the fire operate, spraying water to control or put out the fire while it's still small.
What the law says
Building Regulations — Approved Document B
New blocks of flats over 11 metres in England must have sprinklers (since November 2020). Some care homes, large warehouses and other buildings need them too.
Regulatory Reform (Fire Safety) Order 2005
Once fitted, sprinklers must be maintained.
Standards we work to
- BS EN 12845 — Design, installation and maintenance of commercial sprinkler systems.
- BS 9251 — Sprinklers for homes, flats, HMOs and care homes.
Who is responsible?
The building owner or responsible person.
The components we install
These are the parts that make up a typical sprinkler systems installation, what each one does, and what a healthy one looks like.
Sprinkler head
Has a small glass bulb full of liquid. At about 68°C (red bulb) the bulb bursts and water flows.
What to look for: Not painted, not covered, not hung on.
Pipework
Usually steel or special plastic (CPVC) running to each head.
What to look for: No leaks, no corrosion, not used as a hanger.
Alarm valve set
The main control point. Detects water flowing and raises the alarm.
What to look for: Valves locked in the correct position.
Water supply / tank
Mains or a stored tank big enough to run the system for the design time.
What to look for: Tank full, no leaks.
Pump set
Boosts pressure where mains water isn't enough.
What to look for: Runs on weekly test.
Flow switch
Tells the fire alarm that water is flowing.
What to look for: Linked to the alarm panel.
Test and drain valve
Used by engineers to test the system.
What to look for: Closed and labelled.
How often it must be checked
- Weekly (commercial)Check pressures, water levels, valves, and run pumps.By: Site staff
- Yearly (minimum)Full service and inspection.By: Competent sprinkler engineer
Paperwork you should get
- Installation / commissioning certificate — Proves the system matches its design.
- Service report — After each service.
- Log book — Weekly checks and any operations recorded.
Simple checks you can do
- Keep at least 0.5 m clear below heads (more for storage).
- Never paint a head or hang things from pipes.
- Check valves are locked open and pressures look normal.
Common questions
Will all the sprinklers go off at once like in films?
No. Each head works on its own heat. Most fires are controlled by one or two heads.
Need this installed, tested or certified?
We install, service and certify this equipment and hand you every certificate in plain English.